Record Details

The Effect of The Electrochemical Deposition Potential Variation on The Coating of Hydroxyatite on Commertialy pure Titanium (CpTi) and Ti-6Al-4V Alloy

Baghdad Science Journal

View Archive Info
 
 
Field Value
 
Title The Effect of The Electrochemical Deposition Potential Variation on The Coating of Hydroxyatite on Commertialy pure Titanium (CpTi) and Ti-6Al-4V Alloy
 
Creator Journal, Baghdad Science
 
Description In this research we investigated the corrosion behavior of the commertialy pure titanium and Ti-6Al-4V alloy that coated with hydroxyapatite by electrochemical deposition with applied voltage (6,9,12) Volt from aqueous solution containing Ca(NO3)2.H2O =7.0 gm/l , (NH4)2HPO4 =3.5 gm/l , Na(NO3)2 = 8.5 gm/l in order to improve the bonding strength of hydroxyapetite and medical metals and alloys and increasing the biocompatibility. The coating layer morphology was investigated by XRD, Optical microscope , and SEM tests, the corrosio tests was made by use senthesys simulated body fluid (SBF) , and we found that the propreate voltage for coatint on Ti was 9 Volt and for Ti-6Al-4Vwas12Volt.
 
Publisher College of Science for Women - University of Baghdad
 
Date 2015-12-06
 
Type info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Peer-reviewed Article
 
Format application/pdf
 
Identifier http://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/2115
 
Source مجلة بغداد للعلوم; مجلد 12 عدد 4 (2015): issue 4; 684-690
Baghdad Science Journal; Vol 12 No 4 (2015): issue 4; 684-690
2411-7986
2078-8665
 
Language eng
 
Relation http://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/2115/2046
 
Rights Copyright (c) 2015 Baghdad Science Journal